9
TI
New Delhi metallo-β-lactamase-producing carbapenem-resistant Escherichia coli associated with exposure to duodenoscopes.
AU
Epstein L, Hunter JC, Arwady MA, Tsai V, Stein L, Gribogiannis M, Frias M, Guh AY, Laufer AS, Black S, Pacilli M, Moulton-Meissner H, Rasheed JK, Avillan JJ, Kitchel B, Limbago BM, MacCannell D, Lonsway D, Noble-Wang J, Conway J, Conover C, Vernon M, Kallen AJ
SO
JAMA. 2014 Oct;312(14):1447-55.
 
IMPORTANCE: Carbapenem-resistant Enterobacteriaceae (CRE) producing the New Delhi metallo-β-lactamase (NDM) are rare in the United States, but have the potential to add to the increasing CRE burden. Previous NDM-producing CRE clusters have been attributed to person-to-person transmission in health care facilities.
OBJECTIVE: To identify a source for, and interrupt transmission of, NDM-producing CRE in a northeastern Illinois hospital.
DESIGN, SETTING, AND PARTICIPANTS: Outbreak investigation among 39 case patients at a tertiary care hospital in northeastern Illinois, including a case-control study, infection control assessment, and collection of environmental and device cultures; patient and environmental isolate relatedness was evaluated with pulsed-field gel electrophoresis (PFGE). Following identification of a likely source, targeted patient notification and CRE screening cultures were performed.
MAIN OUTCOMES AND MEASURES: Association between exposure and acquisition of NDM-producing CRE; results of environmental cultures and organism typing.
RESULTS: In total, 39 case patients were identified from January 2013 through December 2013, 35 with duodenoscope exposure in 1 hospital. No lapses in duodenoscope reprocessing were identified; however, NDM-producing Escherichia coli was recovered from a reprocessed duodenoscope and shared more than 92% similarity to all case patient isolates by PFGE. Based on the case-control study, case patients had significantly higher odds of being exposed to a duodenoscope (odds ratio [OR], 78 [95% CI, 6.0-1008], P < .001). After the hospital changed its reprocessing procedure from automated high-level disinfection with ortho-phthalaldehyde to gas sterilization with ethylene oxide, no additional case patients were identified.
CONCLUSIONS AND RELEVANCE: In this investigation, exposure to duodenoscopes with bacterial contamination was associated with apparent transmission of NDM-producing E coli among patients at 1 hospital. Bacterial contamination of duodenoscopes appeared to persist despite the absence of recognized reprocessing lapses. Facilities should be aware of the potential for transmission of bacteria including antimicrobial-resistant organisms via this route and should conduct regular reviews of their duodenoscope reprocessing procedures to ensure optimal manual cleaning and disinfection.
AD
Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, Atlanta, Georgia2Epidemic Intelligence Service, Division of Scientific Education and Professional Development, Centers for Disease Control and Prevention, Atlanta, Georg.
PMID
17
TI
Gastrointestinal endoscopes: a need to shift from disinfection to sterilization?
AU
Rutala WA, Weber DJ
SO
JAMA. 2014 Oct;312(14):1405-6.
 
AD
Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill2Division of Infectious Diseases, University of North Carolina School of Medicine, Chapel Hill.
PMID