UpToDate
Official reprint from UpToDate®
www.uptodate.com ©2017 UpToDate®

Medline ® Abstract for Reference 42

of 'Operative vaginal delivery'

42
TI
Failed individual and sequential instrumental vaginal delivery: contributing risk factors and maternal-neonatal complications.
AU
Al-Kadri H, Sabr Y, Al-Saif S, Abulaimoun B, Ba'Aqeel H, Saleh A
SO
Acta Obstet Gynecol Scand. 2003;82(7):642.
 
BACKGROUND: To identify the risk factors for failed instrumental vaginal delivery, and to compare maternal and neonatal morbidity associated with failed individual and sequential instruments used.
DESIGN: A retrospective case-control study.
METHODS: From January 1995 to June 2001, there were 39 508 live births at>37 weeks' gestation of which 2628 (6.7%) instrumental vaginal deliveries were performed, 1723 (4.4%) were vacuum extractions and 905 (2.3%) were forceps. A total of 155/2628 (5.9%) patients who had failed instrumental delivery were matched with 204 patients who had successful instrumental delivery. The patients were divided into five groups. Group I (n = 129) had failed vacuum extraction, group II (n = 13) failed forceps, group III (n = 13) failed both (i.e. failed attempt at both instruments sequentially), group IV (n = 138) had successful vacuum extraction and group V (n = 66) successful forceps.
RESULTS: The failurerate for vacuum extractions 129/1723 (7.5%) was significantly higher than that for forceps 13/905 (1.4%) [odds ratio (OR) = 5.6, 95% CI 3-10.3]. There were no significant differences in all maternal complications (25.5% vs. 26.6%) between vacuum (groups I and IV) and forceps (groups II and V) assisted deliveries. There were more maternal complications in group III (46.2%) than in groups I (35.7%), II (23.1%) and V (27.3%) that did not reach statistical significance but were significantly higher than in group IV (15.9%, OR = 4.5, 95% CI 1.2-16.9). There was a significantly higher rate of all fetal complications in group III [11/13 (84.6%)]than in groups I [69/129 (53.5%)], II [7/13 (53.8%)], IV [35/138 (25.4%)]and V [22/66 (33.3%)](OR = 4.8, 95% CI 0.9-19.9).
CONCLUSIONS: Applying the instrument at<or =0 fetal station, nulliparous women, history of previous cesarean section and fetal head other than occipitoanterior position were risk factors for failed instrumental delivery. Sequential use of instrumental delivery carries a significantly higher neonatal morbidity than when a single instrument is used.
AD
Department of Obstetrics and Gynecology, King Fahad National Guard Hospital, Riyadh, Saudi Arabia.