Medline ® Abstract for Reference 16
of 'Noninvasive assessment of hepatic fibrosis: Ultrasound-based elastography'
16
TI
Is ARFI elastography reliable for predicting fibrosis severity in chronic HCV hepatitis?
AU
Sporea I, Sirli R, Bota S, Fierbinţeanu-Braticevici C, Petrişor A, Badea R, Lupşor M, Popescu A, DănilăM
SO
World J Radiol. 2011 Jul;3(7):188-93.
AIM:
To determine whether acoustic radiation force impulse (ARFI) elastography is a reliable method for predicting fibrosis severity in patients with chronic hepatitis C virus (HCV) hepatitis.
METHODS:
We performed a multicenter study including 274 subjects with HCV chronic hepatitis in which we compared ARFI with liver biopsy (LB). In each patient we performed LB (evaluated according to the Metavir score) and ARFI measurements (using a Siemens Acuson S2000™ultrasound system: 10 valid measurements were performed and median values were calculated and expressed in meters/second (m/s).
RESULTS:
A direct, strong, correlation (Spearman r = 0.707) was found between ARFI measurements and fibrosis (P<0.0001). For predicting the presence of fibrosis (F≥1 Metavir), significant fibrosis (F≥2), severe fibrosis (F≥3) and cirrhosis (F = 4), the cut-off values of 1.19, 1.21, 1.58 and 1.82 m/s were determined, respectively, liver stiffness measurements had 73%, 84%, 84% and 91% Se respectively; 93%, 91%, 94%, 90% Sp, respectively; with AUROCs of 0.880, 0.893, 0.908 and 0.937, respectively.
CONCLUSION:
ARFI measurement is a reliable method for predicting the severity of fibrosis in HCV patients.
AD
Ioan Sporea, RoxanaŞirli, Simona Bota, Alina Popescu, Mirela Dănilă, Department of Gastroenterology and Hepatology, University of Medicine and Pharmacy Timişoara, 10 Iosif Bulbuca Bv., 300736 Timisoara, Romania.
PMID
