UpToDate
Official reprint from UpToDate®
www.uptodate.com ©2017 UpToDate®

Medline ® Abstract for Reference 67

of 'Interferon-gamma release assays for diagnosis of latent tuberculosis infection'

67
TI
Decay kinetics of an interferon gamma release assay with anti-tuberculosis therapy in newly diagnosed tuberculosis cases.
AU
Adetifa IM, Ota MO, Walther B, Hammond AS, Lugos MD, Jeffries DJ, Donkor SA, Adegbola RA, Hill PC
SO
PLoS One. 2010;5(9) Epub 2010 Sep 1.
 
BACKGROUND: Qualitative and quantitative changes in IGRA response offer promise as biomarkers to monitor Tuberculosis (TB) drug therapy, and for the comparison of new interventions. We studied the decay kinetics of TB-specific antigen T-cell responses measured with an in-house ELISPOT assay during the course of therapy.
METHODS: Newly diagnosed sputum smear positive TB cases with typical TB chest radiographs were recruited. All patients were given standard anti-TB treatment. Each subject was followed up for 6 months and treatment outcomes were documented. Blood samples were obtained for the ESAT-6 and CFP-10 (EC) ELISPOT at diagnosis, 1-, 2-, 4- and 6-months. Qualitative and quantitative reversion of the ELISPOT results were assessed with McNemar test, conditional logistic regression and mixed-effects hierarchical Poisson models.
RESULTS: A total of 116 cases were recruited and EC ELISPOT was positive for 87% (95 of 109) at recruitment. There was a significant decrease in the proportion of EC ELISPOT positive cases over thetreatment period (p<0.001). Most of the reversion occurred between the start and first month of treatment and at completion at 6 months. ESAT-6 had higher median counts compared to CFP-10 at all time points. Counts for each antigen declined significantly with therapy (p<0.001). Reverters had lower median SFUs at the start of treatment compared to non-Reverters for both antigens. Apart from the higher median counts for non-Reverters, no other risk factors for non-reversion were found.
CONCLUSIONS: TB treatment induces qualitative and quantitative reversion of a positive in-house IGRA in newly diagnosed cases of active TB disease. As this does not occur reliably in the majority of cured individuals, qualitative and quantitative reversion of an IGRA ELISPOT has limited clinical utility as a surrogate marker of treatment efficacy.
AD
Bacterial Diseases Programme, Medical Research Council (United Kingdom) Laboratories, Fajara, The Gambia. iadetifa@mrc.gm
PMID